3com S7906E 설치 설명서
1-6
Basic Configuration Tasks
Basic configuration tasks include:
z
z
z
Based on the network design, you should configure MEPs or the rules for generating MIPs on each
device. However, before doing this you must first configure the service instance.
Configuring Service Instance
A service instance is indicated by an integer to represent an MA in an MD. The MD and MA define the
level and VLAN attribute of the messages handled by the MPs in a service instance.
Follow these steps to configure a service instance:
To do...
Use the command...
Remarks
Enter system view
system-view
—
Enable CFD
cfd enable
Required
CFD is disabled by default.
Configure the CFD protocol
version
version
cfd version { draft5 |
standard }
standard }
Optional
By default, CFD uses the
standard version of IEEE
802.1ag.
standard version of IEEE
802.1ag.
Create an MD
cfd md md-name level
level-value
level-value
Required
Not created by default
Create an MA
cfd ma ma-name md md-name
vlan vlan-id
vlan vlan-id
Required
Not created by default
Create a service instance
cfd service-instance
instance-id md md-name ma
ma-name
instance-id md md-name ma
ma-name
Required
Not created by default
z
These configuration tasks are the foundation for other CFD configuration tasks.
z
The last three steps in the table above must be performed strictly in order.
z
The CFD protocol version used on different devices in an MD must be consistent; otherwise, the
devices cannot exchange CFD protocol packets.