3com S7906E 설치 설명서

다운로드
페이지 2621
 
1-6 
Basic Configuration Tasks 
Basic configuration tasks include: 
 
 
Based on the network design, you should configure MEPs or the rules for generating MIPs on each 
device. However, before doing this you must first configure the service instance. 
 
Configuring Service Instance 
A service instance is indicated by an integer to represent an MA in an MD. The MD and MA define the 
level and VLAN attribute of the messages handled by the MPs in a service instance. 
Follow these steps to configure a service instance: 
To do... 
Use the command... 
Remarks 
Enter system view 
system-view 
— 
Enable CFD 
cfd enable 
Required 
CFD is disabled by default.  
Configure the CFD protocol 
version 
cfd version { draft5 | 
standard } 
Optional 
By default, CFD uses the 
standard version of IEEE 
802.1ag. 
Create an MD 
cfd md md-name level 
level-value 
Required 
Not created by default 
Create an MA 
cfd ma ma-name md md-name 
vlan 
vlan-id 
Required 
Not created by default 
Create a service instance 
cfd service-instance 
instance-id md md-name ma 
ma-name 
Required 
Not created by default 
 
 
These configuration tasks are the foundation for other CFD configuration tasks. 
The last three steps in the table above must be performed strictly in order. 
The CFD protocol version used on different devices in an MD must be consistent; otherwise, the 
devices cannot exchange CFD protocol packets.