[Sysname] user-interface aux 0 
# Specify not to authenticate the user logging in through the Console port. 
[Sysname-ui-aux0] authentication-mode none 
# Specify commands of level 2 are available to the user logging in to the AUX user interface. 
[Sysname-ui-aux0] user privilege level 2 
# Set the baud rate of the Console port to 19200 bps. 
[Sysname-ui-aux0] speed 19200 
# Set the maximum number of lines the screen can contain to 30. 
[Sysname-ui-aux0] screen-length 30 
# Set the maximum number of commands the history command buffer can store to 20. 
[Sysname-ui-aux0] history-command max-size 20 
# Set the timeout time of the AUX user interface to 6 minutes. 
[Sysname-ui-aux0] idle-timeout 6 
After the above configuration, to ensure a successful login, the console user needs to change the 
corresponding configuration of the terminal emulation program running on the PC, to make the 
configuration consistent with that on the switch. Refer to 
 
for details. 
Console Port Login Configuration with Authentication Mode Being 
Password 
Configuration Procedure 
Follow these steps to perform Console port login configuration (with authentication mode being 
password): 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Enter AUX user interface 
view 
user-interface aux 
first-number [ last-number ]
— 
Configure to authenticate 
users using the local 
password 
authentication-mode 
password  
Required 
By default, users logging in through the 
Console port are not authenticated, while 
users logging in through the Telnet need 
to pass the password authentication.  
Set the local password 
set authentication 
password
 { cipher | 
simple password 
Required 
 
Note that if you configure to authenticate the users in the password mode, the command level available 
to users logging in to a switch depends on both the authentication-mode  password and the user 
privilege level level command, as listed in the following table.