3com S7906E 설치 설명서

다운로드
페이지 2621
 
1-21 
 
[SwitchB-GigabitEthernet2/0/2] qinq enable 
# Apply the uplink policy p2 to the inbound direction of GigabitEthernet 2/0/2.  
[SwitchB-GigabitEthernet2/0/2] qos apply policy p2 inbound 
# Apply the downlink policy p22 to the outbound direction of GigabitEthernet 2/0/2.  
[SwitchB-GigabitEthernet2/0/2] qos apply policy p22 outbound 
[SwitchB-GigabitEthernet2/0/2] quit 
# Configure GigabitEthernet 2/0/3 to permit frames of the specified SVLANs to pass through.  
[SwitchB] interface gigabitethernet 2/0/3 
[SwitchB-GigabitEthernet2/0/3] port link-type trunk 
[SwitchB-GigabitEthernet2/0/3] port trunk permit vlan 111 211 311 112 212 312 
3)  Configuration on Switch C 
<SwitchC> system-view 
# Enable DHCP snooping.  
[SwitchC] dhcp-snooping 
# Enable ARP detection on each VLAN involved in VLAN mapping.  
[SwitchC] vlan 101 
[SwitchC-vlan101] arp detection enable 
[SwitchC-vlan101] vlan 201 
[SwitchC-vlan201] arp detection enable 
[SwitchC-vlan201] vlan 301 
[SwitchC-vlan301] arp detection enable 
[SwitchC-vlan301] vlan 102 
[SwitchC-vlan102] arp detection enable 
[SwitchC-vlan102] vlan 202 
[SwitchC-vlan202] arp detection enable 
[SwitchC-vlan202] vlan 302 
[SwitchC-vlan302] arp detection enable 
[SwitchC-vlan302] vlan 111 
[SwitchC-vlan111] arp detection enable 
[SwitchC-vlan111] vlan 211 
[SwitchC-vlan211] arp detection enable 
[SwitchC-vlan211] vlan 311 
[SwitchC-vlan311] arp detection enable 
[SwitchC-vlan311] vlan 112 
[SwitchC-vlan112] arp detection enable 
[SwitchC-vlan112] vlan 212 
[SwitchC-vlan212] arp detection enable 
[SwitchC-vlan212] vlan 312 
[SwitchC-vlan312] arp detection enable 
[SwitchC-vlan312] vlan 501 
[SwitchC-vlan501] arp detection enable 
[SwitchC-vlan501] vlan 502 
[SwitchC-vlan502] arp detection enable 
[SwitchC-vlan502] vlan 503