1-29 
Configuring MPLS VPN Time Synchronization in Symmetric Peers Mode  
Network requirements 
PE 1’s local clock is to be used as a reference source, with the stratum level of 1. 
PE 2 is synchronized to PE 1 in the symmetric peers mode. 
Configuration procedure 
1)  Configuration on PE 1:  
# Specify the local clock as the reference source, with the stratum level of 1.  
<PE1> system-view 
[PE1] ntp-service refclcok-master 1 
2)  Configuration on PE 2:  
# Specify PE 1 in VPN 1 as the symmetric-passive peer of PE 2.  
<PE2> system-view 
[PE2] ntp-service unicast-peer vpn-instance vpn1 10.1.1.2 
# View the NTP session information and status information on PE 2 a certain period of time later. The 
information should show that PE 2 has been synchronized to PE 1, with the clock stratum level of 2.  
[PE2] display ntp-service status 
 Clock status: synchronized 
 Clock stratum: 2 
 Reference clock ID: 10.1.1.2 
 Nominal frequency: 99.9100 Hz  
 Actual frequency: 99.9100 Hz  
 Clock precision: 2^18 
 Clock offset: 0.0000 ms 
 Root delay: 32.00 ms 
 Root dispersion: 0.60 ms 
 Peer dispersion: 7.81 ms 
 Reference time: 02:44:01.200 UTC Jan 1 2001(BDFA6D71.33333333) 
[PE2] display ntp-service sessions 
source          reference       stra reach poll  now offset  delay disper 
************************************************************************** 
[12345]10.1.1.2       LOCL          1    1   64   29    -12.0   32.0    15.6 
note: 1 source(master),2 source(peer),3 selected,4 candidate,5 configured    
Total associations :  1      
[PE2] display ntp-service trace    
 server 127.0.0.1,stratum 2, offset -0.012000, synch distance 0.02448 
 server 10.1.1.2,stratum 1, offset 0.003500, synch distance 0.00781 
 refid 127.127.1.0