3com S7906E 설치 설명서

다운로드
페이지 2621
 
3-14 
To do... 
Use the command... 
Remarks 
Enable traffic encryption 
encrypt enable 
Optional 
By default, data encryption is 
enabled for downlink data. 
Configure an encryption key 
encrypt key key-value 
Optional 
If no encryption key is 
configured, the system uses 
the default encryption key. 
Currently, the encrypt key 
command is not supported.  
 
Testing the Link Between an ONU and the OLT 
Follow these steps to test the optical link between an ONU and the OLT: 
To do... 
Use the command... 
Remarks 
Enter system view 
system-view
 
— 
Enter ONU port view 
interface
 onu 
interface-number
 
— 
Test the optical link between 
the ONU and the OLT 
linktest
 [ frame-number value 
frame-size value | delay { on | 
off
 } | vlan-tag { on 
[ vlan-priority value | vlan-id 
value
 ] | off } ] * 
Required 
The following lists the default 
values of the link test 
parameters. 
 
Number of test frames: 20 
 
Frame size: 1000 bytes 
 
VLAN tag: not carried in 
testing frames 
 
Delay testing state: Off 
 
 
The link connectivity between an ONU and the OLT can be tested only when the ONU is online. 
 
Testing the Cable Connected to an UNI Port 
Perform this operation to test the cable connected to the specified UNI port of the ONU once and to 
display the testing result.  
Follow these steps to test the cable connected to an UNI port: 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Enter ONU port view 
interface
 onu 
interface-number
 
— 
Test the cable connected to an 
UNI port 
uni uni-number 
virtual-cable-test
 
Required