3com S7906E 참조 가이드

다운로드
페이지 2327
 
1-1 
1  
Basic Configuration Commands 
Basic Configuration Commands 
clock datetime 
Syntax 
clock datetime time date 
View 
User view 
Default Level 
3: Manage level 
Parameters 
time: Time in the format of HH:MM:SS, where HH is hours in the range 0 to 23, MM is minutes in the 
range 0 to 59, and SS is seconds in the range 0 to 59. The zeros in the argument can be omitted except 
for indicating 0 hours. 
date: Date in the format of MM/DD/YYYY or YYYY/MM/DDMM is the month of the year in the range 1 
to 12, DD is the day of the month that varies with months, and YYYY is a year in the range 2000 to 2035. 
Description 
Use the clock datetime command to set the current time and date of the device. 
The current time and date of the device must be set in an environment that requires the acquisition of 
absolute time. 
You may choose not to provide seconds when inputting the time parameters. 
Related commands: clock summer-time one-offclock summer-time repeatingclock timezone
display clock
Examples 
# Set the current system time to 14:10:20 08/01/2005. 
<Sysname> clock datetime 14:10:20 8/1/2005 
# Set the current system time to 00:06:00 01/01/2007. 
<Sysname> clock datetime 0:6 2007/1/1 
clock summer-time one-off 
Syntax 
clock summer-time zone-name one-off start-time start-date end-time end-date add-time 
undo clock summer-time