3com S7906E 참조 가이드

다운로드
페이지 2327
 
1-13 
View 
System view 
Default Level 
2: System level 
Parameters 
threshold-value: Errored frame period event triggering threshold, ranging from 0 to 4294967295. 
Description 
Use the oam errored-frame-period threshold command to set the errored frame period event 
triggering threshold. 
Use the undo oam errored-frame-period threshold command to restore the default. 
By default, the errored frame period event triggering threshold is 1. 
A errored frame period event occurs when a errored frame period detection interval expires and the 
number of the frame errors occurred on an Ethernet port is larger than (or equal to) the errored frame 
period event triggering threshold. 
The errored frame period event triggering threshold configured applies to all the Ethernet ports on which 
OAM connections are established. 
Related commands: oam  errored-frame-period period,  display oam link-event,  display oam 
configuration
Examples 
# Set the errored frame period event triggering threshold to 100. 
<Sysname> system-view 
[Sysname] oam errored-frame-period threshold 100 
oam errored-frame-seconds period 
Syntax 
oam errored-frame-seconds period period-value 
undo oam errored-frame-seconds period 
View 
System view 
Default Level 
2: System level 
Parameters 
period-value: Errored frame seconds detection interval, ranging from 10 to 900 (in seconds). 
Description 
Use the oam errored-frame-seconds period command to set the errored frame seconds detection 
interval.