3com S7906E 참조 가이드

다운로드
페이지 2327
 
1-5 
After LT messages automatic sending is enabled, if a MEP fails to receive the CCMs from the 
remote MEP, the link between the two is regarded as faulty and LTMs will be sent out. (The 
destination of the LTMs is the remote MEP, and the maximum value of TTL is 255.) Based on the 
LTRs that echo back, the fault source can be located. 
Once you disable LT messages automatic sending, the content stored in the buffer will be 
removed. 
Related commands: cfd linktrace
Examples 
# Enable automatic LT messages sending. 
<Sysname> system-view 
[Sysname] cfd linktrace auto-detection  
cfd loopback 
Syntax 
cfd loopback service-instance instance-id mep mep-id  {  target-mep  target-mep-id | target-mac 
mac-address } [ number loopback-number ] 
View 
System view 
Default level 
2: System level 
Parameters 
service-instance instance-id: Specifies the service instance ID, ranging from 1 to 32767. 
mep mep-id: Specifies the ID of a MEP, ranging from 1 to 8191. 
target-mep target-mep-id: Specifies the ID of the destination MEP for LBM packets, ranging from 1 to 
8191. 
target-mac mac-address: Specifies the destination MAC address, in the format of H-H-H. 
number loopback-number: Specifies the number of the LBMs packets sent, ranging from 1 to 10 and 
defaulting to 5. 
Description 
Use the cfd loopback command to enable LB function so that LBMs can be sent from the specified 
MEP to other MEPs in the same service instance, and LBR messages can be received. 
By default, LB is not enabled. 
Examples 
# Enable LB to check link state. 
<Sysname> system-view 
[Sysname] cfd loopback service-instance 1 mep 1101 target-mep 2001 
Loopback to 0010-FC00-6512 with the sequence number start from 1101-43404: 
Reply from 0010-FC00-6512: sequence number=1101-43404  
Reply from 0010-FC00-6512: sequence number=1101-43405