3-11 
<Sysname> system-view 
[Sysname] interface onu 1/0/1:1 
[Sysname-Onu1/0/1:1] alarm oam error-frame-period window 2 threshold 30 
alarm oam error-frame-period enable 
Syntax 
alarm oam error-frame-period enable 
undo alarm oam error-frame-period enable 
View 
OLT port view, ONU port view, FTTH view 
Default Level 
2: System level 
Parameters 
None
 
Description 
Use the alarm oam error-frame-period enable command to enable the error frame period alarm. 
Use the undo alarm oam error-frame-period enable command to disable the error frame period 
alarm. 
By default, the error frame period alarm is enabled.  
 
 
The commands here take effect only for OAM 2.0 and above.  
 
Examples 
# Enable the error frame period alarm for the ONU corresponding to ONU 3/0/1:1. 
<Sysname> system-view 
[Sysname] interface onu 3/0/1:1 
[Sysname-Onu3/0/1:1] alarm oam error-frame-period enable 
alarm oam error-frame 
Syntax 
alarm oam error-frame window window threshold threshold } 
undo alarm oam error-frame { window | threshold } 
View 