<Sysname> system-view
[Sysname] mpls
[Sysname-mpls] mpls te timer auto-bandwidth 600 
mpls te timer fast-reroute
Syntax
mpls te timer fast-reroute [ seconds]
undo mpls te timer fast-reroute
View
MPLS view
Parameter
seconds: FRR polling timer setting for the point of local repair (PLR) to poll 
available bypass tunnels for the best one. It ranges from 0 to 604800 seconds, 
with 0 disabling the PLR to poll available bypass tunnels regularly for the best one. 
The default is 300 seconds or 5 minutes.
Description
Use the mpls te timer fast-reroute command to set the FRR polling timer.
Use the undo mpls te timer fast-reroute command to disable FRP polling.
The default FRR polling timer is 300 seconds.
n
This command is not supported when the signaling protocol is CR-LDP.
Example
# Set the FRR polling timer to 120 seconds or 2 minutes.
<Sysname> system-view
[Sysname] mpls
[Sysname-mpls] mpls te timer fast-reroute 120 
mpls te timer retry
Syntax
mpls te timer retry second
undo mpls te timer retry
View
Tunnel interface view
Parameter
second: Interval for re-establishing the tunnel, in the range 1 to 4294967295 
seconds.
Description
Use the mpls te timer retry command to configure the interval for 
re-establishing the tunnel.
Use the undo mpls te timer retry command to restore the default.
The default interval for re-establishing a tunnel is 10 seconds.