3com MSR 20-20 참조 매뉴얼

다운로드
페이지 2742
210
C
HAPTER
 12: F
UNDAMENTAL
 CE1/PRI I
NTERFACE
 C
ONFIGURATION
 C
OMMANDS
loopback (CE1/PRI interface view)
Syntax
loopback { local | payload | remote }
undo loopback
View
CE1/PRI interface view
Parameter
local: Sets the interface in local loopback mode.
remote: Sets the interface in external loopback mode.
payload: Sets the interface in external payload loopback mode.
Description
Use the loopback command to enable loopback and set the loopback mode.
Use the undo loopback command to restore the default.
By default, loopback is disabled.
Loopback is intended for checking the condition of interfaces or cables. Disable it 
otherwise.
You can bundle timeslots on the CE1/PRI interface to form a serial interface and 
encapsulate it with PPP. After you enable loopback on this serial interface, it is 
normal that the state of the link layer protocol is reported down.
Example
# Set interface E1 2/0 in internal loopback mode.
<Sysname> system-view
[Sysname] controller e1 2/0
[Sysname-E1 2/0] loopback local 
pri-set (CE1/PRI interface view)
Syntax
pri-set [ timeslot-list list ]
undo pri-set
View
CE1/PRI interface view
Parameter
timeslot-list list: Specifies timeslots to be bundled. The list argument is timeslot 
numbers, in the range of 1 to 31. You may specify a single timeslot by specifying a 
number, a range of timeslots by specifying a range in the form of 
number1-number2, or several discrete timeslots by specifying number1
number2-number3.
Description
Use the pri-set command to bundle timeslots on the CE1/PRI interface into a PRI 
set.