3com MSR 20-20 참조 매뉴얼

다운로드
페이지 2742
216
C
HAPTER
 13: F
UNDAMENTAL
 CT1/PRI I
NTERFACE
 C
ONFIGURATION
 C
OMMANDS
Parameter
set-number: The number of the channel set formed by timeslot bundling on the 
interface. It ranges from 0 to 23.
timeslot-list list: Specifies timeslots to be bundled. The list argument is timeslot 
numbers, in the range of 1 to 24. You may specify a single timeslot by specifying a 
number, a range of timeslots by specifying a range in the form of 
number1-number2, or several discrete timeslots by specifying number1
number2-number3.
speed { 56k | 64k }: Speed of the timeslot bundle (the channel set) in kbps. If 56k 
is selected, the timeslots is bundled into N 
× 56 kbps bundles. If 64k, the default, 
is selected, the timeslots is bundled into N 
× 64 kbps bundles.
Description
Use the channel-set command to bundle timeslots on the CT1/PRI interface into 
a channel set.
Use the undo channel-set command to remove a specified or all channel sets.
By default, no timeslots are bundled into channel sets.
A CT1/PRI interface is physically divided into 24 timeslots numbered 1 through 24. 
In actual applications, all the timeslots can be bundled into multiple channel sets. 
For each channel set, the system automatically creates a serial interface logically 
equivalent to a synchronous serial interface.
The serial interface is named in the form of serial interface-number:set-number
where interface-number starts from the maximum serial interface number plus 1, 
and set-number represents the number of the channel set.
Only one timeslot bundling mode is supported on a CT1/PRI interface at a time. In 
other words, you cannot use this command together with the pri-set command.
Example
# Bundle timeslots 1, 2, 5, 10 through 15, and 18 into channel set 0 on CT1/PRI 
interface T1 2/0.
<Sysname> system-view
[Sysname] controller t1 2/0
[Sysname-T1 2/0] channel-set 0 timeslot-list 1,2,5,10-15,18 
clock (CT1/PRI interface view)
Syntax
clock { master | slave }
undo clock
View
CT1/PRI interface view
Parameter
master: Adopts the internal clock as the clock source.
slave: Adopts the line clock as the clock source.
Description
Use the clock command to configure clock source for the CT1/PRI interface.