data-fill
Syntax
data-fill string
undo data-fill
View
ICMP-echo/UDP-echo/UDP-jitter test type view
Parameter
string: String of fill characters of a probe packet, in the range 1 to 200. It is case 
sensitive.
Description
Use the data-fill command to configure the string of fill characters of a probe 
packet.
Use the undo data-fill command to restore the default.
By default, the string of fill characters of a probe packet is the string 
corresponding to the ASCII code 00 to 09.
If the probe packet is smaller than the fill data, the system uses only the first 
part of the character string to encapsulate the packet.
If the probe packet is larger than the fill data, the system fills the character 
string cyclically to encapsulate the packet until it is full.
For example, when the fill data is abcd and the size of a probe packet is 3 byte, 
abc is used to fill the packet. When the probe size is 6 byte, abcdab is used to fill 
the packet.
Because the first five bytes of a probe packet in a UDP-echo test have some 
specific usage, the configured character string is used to fill the remaining bytes 
in the probe packet.
Because the first 68 bytes of a probe packet in UDP-jitter test have some 
specific usage, the configured character string is used to fill the remaining bytes 
in the probe packet.
Example
# Configure the string of fill characters of an ICMP-echo probe packet as abcd.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type icmp-echo
[Sysname-nqa-admin-test-icmp-echo] data-fill abcd