C
HAPTER
 169: ACSEI S
ERVER
 C
ONFIGURATION
 C
OMMANDS
acsei timer clock-sync
Syntax
acsei timer clock-sync minutes
undo acsei timer clock-sync
View
ACSEI server view
Parameters
minutes: Value of the synchronization timer that is used for clock synchronization 
from ACSEI server to ACSEI client. It ranges from 0 to 1440 (in minutes), where 
value 0 specifies to inhibit the clock synchronization from ACSEI server to ACSEI 
client.
Description
Use the acsei timer clock-sync command to set the synchronization timer that 
is used for clock synchronization from ACSEI server to ACSEI client.
Use the undo acsei timer clock-sync command to restore the default value for 
the synchronization timer.
By default, the sychronization timer is set to five minutes.
Examples
# Set the synchronization timer from ACSEI server to ACSEI client to 20 minutes.
<Sysname> system-view
[Sysname] acsei server
[Sysname-acsei-server] acsei timer clock-sync 20 
acsei timer monitor
Syntax
acsei timer monitor seconds
undo acsei timer monitor
View
ACSEI server view
Parameters
seconds: Value of the monitor timer that is used for ACSEI server to monitor ACSEI 
clients. It ranges from 0 to 10 (in seconds), where 0 specifies to disable ACSEI 
server from monitoring ACSEI client.
Description
Use the acsei timer monitor command to set the monitor timer for ACSEI 
server to monitor ACSEI client.
Use the undo acsei timer monitor command to restore the default value for 
the monitor timer.
By default, the monitor timer is set to five seconds.
Examples
# Set the monitor timer for ACSEI server to monitor ACSEI client to six seconds.