3com MSR 20-20 참조 매뉴얼

다운로드
페이지 2742
2614
C
HAPTER
 173: V
O
IP C
ONFIGURATION
 C
OMMANDS
View
E&M voice subscriber line view
Parameter
seconds: Maximum duration in seconds the system waits for a digit, in the range 
of 3 to 600.
infinity: Infinite time.
Description
Use the timer wait-digit command to configure the maximum time duration 
the system waits for a digit.
Use the undo timer wait-digit command to restore the default time settings.
By default, the maximum time duration the system waits for a digit is 5 seconds.
Example
# Set the maximum duration waiting for the first dial on voice line 1/0 to 5 
seconds.
<Sysname> system-view
[Sysname] voice-setup
[Sysname-voice] subscriber-line 1/0
[Sysname-voice-line1/0] timer wait-digit 5 
transmit gain
Syntax
transmit gain value
undo transmit gain
View
FXS/FXO/E&M voice subscriber line view
Parameter
value: Voice output gain in dB, in the range of -14.0 to 13.9 with one digit after 
the decimal point.
Description
Use the transmit gain command to configure the voice subscriber line output 
end gain value.
Use the undo transmit gain command to restore the default value.
By default, the output gain on the voice interface is 0 dB.
When a relatively small voice signal power is needed on the output line, this 
command can be used to properly increase the voice output gain value to adapt to 
the output line signal requirement.
Related command:
c
CAUTION: Gain adjustment may lead to a call failure. You are not recommended 
to adjust the gain. If necessary, do it with the guidance of technical personnel.
Example
# Configure the voice output gain value as -6.7dB on subscriber line 1/0.