3com MSR 20-20 참조 매뉴얼

다운로드
페이지 2742
2617
<Sysname> system-view
[Sysname] voice-setup
[Sysname-voice] dial-program
[Sysname-voice-dial] entity 10 pots
[Sysname-voice-dial-entity10] vad-on 
vi-card busy-tone-detect
Syntax
vi-card busy-tone-detect { auto index line-number | custom area-number index argu 
f1 f2 p1 p2 p3 p4 p5 p6 p7 
}
undo vi-card busy-tone-detect custom index
View
Voice view
Parameter
index: Index of busy tone type, in the range of 0 to 3.
line-number: Voice subscriber line number. The value range varies with the 
inserted cards.
area-number: Area number. Currently, it is set to 2.
argu: Reserved, in the range of 0 to 32,767.
f1: Frequency 1 in Hz, in the range of 50 to 3,600.
f2: Frequency 2 in Hz, in the range of 50 to 3,600.
p1: Signal amplitude 1, in the range of 50 to 32,767.
p2: Signal amplitude 2, in the range of 50 to 32,767.
p3: Duration of a single tone in milliseconds, in the range of 10 to 1,000.
p4: Duration error of a single tone in milliseconds, in the range of 0 to 500.
p5: Duration of silence in milliseconds, in the range of 10 to 1,000.
p6: Duration error of silence in milliseconds, in the range of 0 to 500.
p7: Absolute difference between p3 and p5 in milliseconds, in the range of 0 to 
500
Description
Use the vi-card busy-tone-detect command to configure the parameters for 
the busy tone detection on the FXO interface.
Use the undo vi-card busy-tone-detect command to restore the default 
settings.
This command applies to the FXO interface only.
The system supports four types of busy tones, which are specified by the index 
argument.