Example
# Display line state of T1 line 1 on CT3 interface T3 2/0.
<Sysname> system-view
[Sysname] interface t3 2/0
[Sysname-T3 2/0] t1 1 show
T3 2/0
CT1 1 is up
Frame-format ESF, clock slave, loopback not set
FDL Performance Report is disabled
Transmitter is sending none
Receiver alarm state is none
Line loop back deactivate code using inband signal last sent
BERT state:(stopped, not completed)
Test pattern: 2^11, Status: Not Sync, Sync Detected: 0
Time: 0 minute(s), Time past: 0 minute(s)
Bit errors (since test started): 0 bits
Bits received (since test started): 0 Kbits
Bit errors (since latest sync): 0 bits
Bits received (since latest sync): 0 Kbits 
t1 shutdown
Syntax
t1 line-number shutdown
Table 22   Description on the fields of the t1 show command
Field Description 
T3 2/0 CT1 1 is up 
The state of T1 line 1 on the CT3 interface: up or down 
Frame-format ESF 
Framing format of T1: ESF or SF 
clock slave 
Clock source used by the T1 line: slave for the line clock or 
master for the internal clock 
loopback not set 
Loopback state or mode: local, remote, payload, or not set. 
FDL Performance Report is 
disabled 
Transmission of PPR in the FDL is disabled. You may enable 
that with the t1 set fdl ansi command. 
Transmitter is sending RAI 
The transmitter of the T1 line is sending RAI signals. When 
the T1 line receives LOS, LOF, or AIS signals, it sends RAI 
signals. 
Receiver alarm state 
The type of alarm signal that the T1 line can receive: LOS, 
LOF, AIS, or RAI. 
Line loop back activate code 
using inband signal last sent 
The loopback code sent last time is in-band LLB activation 
request code. 
BERT state 
BERT test state: running, complete, or stopped (not 
completed) 
Test pattern
Status
Sync Detected 
Test pattern in use, 2^11 in this example; synchronization 
state, and the number of detected synchronizations 
Time
Time past 
The duration of the BERT test and the time that has elapsed 
Bit errors (since test started) 
Number of bit errors received since the start of the BERT 
test 
Bits received (since test started) 
Number of bits received since the start of the BERT test 
Bit errors (since latest sync) 
Number of bit errors received since the last synchronization 
Bits received (since latest sync) 
Number of bits received since the last synchronization