Ethernet interface view
Parameter
mseconds: LLC2 local acknowledgment delay, in milliseconds. The effective range 
is 1 to 60,000.
Description
Use the llc2 timer ack-delay command to configure the LLC2 local 
acknowledgment delay time, namely the maximum length of time the device 
waits before sending an acknowledgment to the peer end upon receiving an LLC2 
frame.
Use the undo llc2 timer ack-delay command to restore the default setting.
By default, the LLC2 local acknowledgment delay time is 100 milliseconds.
Example
# Set the LLC2 local acknowledgment delay time to 200 milliseconds on Ethernet 
1/0.
<Sysname> system-view
[Sysname] interface ethernet 1/0
[Sysname-Ethernet1/0] llc2 timer ack-delay 200 
llc2 timer busy
Syntax
llc2 timer busy mseconds
undo llc2 timer busy
View
Ethernet interface view
Parameter
mseconds: LLC2 busy-station polling interval, in milliseconds. The effective range is 
1 to 60,000. The system default is 300 milliseconds.
Description
Use the llc2 timer busy command to configure the LLC2 busy-station polling 
interval, namely the amount of time the router waits before repelling a busy 
station.
Use the undo llc2 timer busy command to restore the default setting.
Example
# Set the LLC2 busy-station polling interval to 200 milliseconds on Ethernet 1/0.
<Sysname> system-view
[Sysname] interface ethernet 1/0
[Sysname-Ethernet1/0] llc2 timer busy 200 