3com MSR 20-20 사용자 설명서

다운로드
페이지 240
FIC-1POS
191
Interface LEDs
The following figure illustrates the FIC-1G.SHDSL panel:
Figure 233   FIC-1G.SHDSL panel
The following table describes the LEDs on the FIC-1G.SHDSL panel.
Interface Cable
The FIC-1G.SHDSL cards use regular telephone cables for connection.
Connecting the Interface
Cable
You simply need a telephone cable to connect the RJ11 interface on an 
FIC-1G.SHDSL card to PSTN.
FIC-1POS
Introduction
FIC-1POS, the 1-port SDH/SONET interface card, supports interface rates up to 
155.52 Mbps (STM-1/OC-3).
The FIC-1POS uses the protocols such as PPP, Frame Relay and HDLC at the data 
link layer and IP at the network layer. It allows direct transmission of packets over 
SONET/SDH. It supports:
Four types of SFP: multi-mode short-haul (1310 nm), single mode medium-haul 
(1310 nm), single mode long-haul (1310 nm), and single-mode ultra-long haul 
(1550 nm).
155.52 Mbps fractional interface
Interface Attributes
The following table describes the interface attributes of the FIC-1POS.
Interface rate 
In single-pair mode, supports the 
sending/receiving independent 
symmetric rates in the range from 192 
kbps to 2304 kbps in steps of 8 kbps. 
Interface cable 
Telephone cable 
Supported services 
G.SHDSL over telephone lines
Table 135   Interface attributes of the FIC-1G.SHDSL
Attribute FIC-1G.SHDSL 
Table 136   LEDs on the FIC-1G.SHDSL panel
LED Description 
LINK 
OFF means no link is present; ON means a 
link is present. 
ACT 
OFF means no data is being transmitted or 
received; blinking means data is being 
received or/and transmitted.