Gaggia d90 evolution 작동 가이드

다운로드
페이지 49
38
ENGLISH
8 -
PURIFIER REGENERATION
IMPORTANT : Regenerate the purifier at the intervals listed
below:
HARDNESS °F
8 LITRE PURIFIER
12 LITRE PURIFIER
From 00 to 20
regeneration after 1100 l.
regeneration after 1600 l
From 21 to 30
regeneration after 850 l.
regeneration after 1250 l.
From 31 to 40
regeneration after 650 l.
regeneration after 950 l.
From 41 to 60
regeneration after 450 l.
regeneration after 650 l.
-
place the empty 2 litre container under pipe E.
-
shift levers C and D from left to right as shown in fig.8.2 and
remove the cover by loosening knob G, pour in 1.5 kg of
sodium chloride (coarse cooking salt) into the 8-litre purifier
and 2 kg into the 12-litre type.
-
Replace the lid and shift lever from right to left as shown in
fig.8.3 and allow the salted water to drain out of pipe F until
the water is fresh.
-
Shift lever D from right to left as shown in fig.8.4
NB: These regeneration instructions are valid only
providing the purifier is as that indicated in the figures.
Should it fail to correspond proceed as indicated in the
instructions attached to the purifier itself.
Fig. 8.01
A
B
E
F
C
D
G
Fig. 8.02
C
D
C
G
D
Fig. 8.03
Fig. 8.04
F
A
WATER INLET
B
WATER OUTPUT
C
INLET TAP LEVER
D
OUTPUT TAP LEVER
E
DEPRESSURIZER PIPE
F
REGENERATION TUBE
G
COVER KNOB