FIG. 3 CONTROL THERMOSTAT TERMINALS
P1263
CONTROL THERMOSTAT
Location:
 
The control thermostat is located inside the trunk 
on the upper left side of the component bracket.
Test Procedures:
1.   Disconnect the brewer from the power source.
2.   With a voltmeter, check the voltage across the blue 
wire on the control thermostat and red insert on 
terminal block. Connect the brewer to the power 
source. The indication must be 220 to 240 volts. 
3.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to the Wiring 
Diagrams and check the brewer wiring harness.
4.  Gently  remove  the  capillary  bulb  and  grommet 
from the tank.
5.  With a voltmeter, check the voltage across the black 
wire of the control thermostat and the red insert on 
the terminal block, when the control thermostat is 
turned "ON" (Fully clockwise). Connect the brewer 
to the power source. The indication must be  220 
to 240 volts ac. 
6.   Disconnect the brewer from the power source.
FIG. 2 CONTROL THERMOSTAT
P1262
SERVICE (cont.)
7.  Voltage must not be present when the thermostat 
is turned to the "OFF" position.
If voltage is present as described, reinstall the capillary 
tube into the tank to the line 4.5" above the bulb, the 
control thermostat is operating properly.
If  voltage  is  not  present  as  described,  replace  the 
thermostat.
Removal and Replacement:
1.   Remove wires from control thermostat. 
2.  Remove the thermostat capillary bulb by firmly
 
pulling up on the capillary at the tank lid. This will 
disengage the grommet from the tank lid.
3.  Remove the one #8-32 screw securing the control 
thermostat to the component bracket inside the 
trunk.
4.  Slide the grommet to the line 4.5" above the bulb 
on the new capillary tube.
5.   Insert the capillary bulb through the hole in the 
tank lid and press the grommet firmly and evenly 
so that the groove in the grommet fits into the tank 
lid.
6.  Carefully bend the capillary tube so that the tube 
and bulb inside the tank are in the vertical posi-
tion.
NOTE -  The capillary tube must be clear of any electri-
cal termination and not kinked.
7.  Using one #8-32 screw secure the control thermo-
stat to the component bracket inside the trunk.
8.  Refer to Fig. 3 when reconnecting the wires.
9.  Adjust the control thermostat as required.
10860.1  091300
BLK or RED to Thermal Cut-Off
BLU to Terminal Block/Tank 
Heater Switch