FIG. 11 WARMER ELEMENT TERMINALS
WARMER ELEMENT(S)
Location:
 
The warmer element(s) is located under the   warmer 
plate.
Test Procedures:
1.  Disconnect the brewer from the power source.
2.  With a voltmeter, check voltage across the red wire 
to the terminal block and white/red, brown/black or 
violet wire to the "ON/OFF" switch, with the "ON/OFF" 
switch in the "ON" (upper) position. Connect the 
brewer to the power source. The indication must 
be 220 to 240 volts ac
3.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to wiring 
diagrams and check brewer wiring harness.
4.  Remove  the  three  #4-40  screws  securing  the 
warmer assembly to the brewer.
5.  Lift the warmer assembly from the brewer.
6.  Disconnect the two wires from the warmer element 
terminals.
7.  Check the continuity across the two terminals on  
the warmer element.
P1164
FIG. 10 WARMER ELEMENTS
SERVICE (cont.)
10860.1  091300
If continuity is present as described, reconnect the 
red wire, and red/white, brown/black or  violet wires 
on the warmer element.
If continuity is not present as described, replace the 
warmer element.
Removal and Replacement:
1.  Remove  the  three  #4-40  screws  securing  the 
warmer assembly to the brewer.
2.  Lift the warmer assembly from the brewer.
3.  Disconnect the two wires from the warmer element 
terminals.
4.  Remove the two #8-32 nuts securing the warmer 
element to the warmer plate.
5.  Securly install new warmer element.
6.  Reconnect the two wires to the warmer element 
terminals.
7.  Securly install warmer assembly on the brewer.
8.   Refer to Fig. 11 when reconnecting the wires.
WHI/RED to ON/OFF Switch
BRN/BLK to ON/OFF Switch
VIO to ON/OFF Switch
RED to Terminal Block