ULTRAGAIN PRO MIC2200
+
Never use unbalanced XLR connections with microphone cables, as this would short-circuit
any phantom power transmitted over these cables!
4. CONTROL  ELEMENTS
4.1 Front panel control elements
Fig. 4.1: Control elements on the front panel
1
This +48 V switch activates the +48 V phantom power circuit that uses the signal leads to supply
condenser microphones with the required operating voltage.
+
Please  check  the  connected  signal  source  for  matching  specifications  before  you  switch
phantom power on, so as to avoid damage to the microphone, etc.
2
Use the MIC/LINE switch to toggle between MIC and LINE modes. When the switch is pressed, the unit
works in MIC mode (now you can press the +48 V switch if required; in LINE mode this function is
disabled).
+
Please note that the input phone jack is disabled in MIC mode, i.e. you must use the XLR
connector to access the microphone amp.
3
The MIC GAIN control is enabled in MIC mode only and allows for applying gain from 10 to 60 dB to the
input signal. In view of the extremely high gain levels that can be applied, you should verify that the gain
control is properly set before you power up the unit. In case of doubt, set the control fully counter-
clockwise, and start from there slowly raising the gain. High gain settings and the resulting levels can
damage subsequent devices.
4
The CLIP LED signals that a level of at least +18 dBu is present after the microphone amp stage. With
too high a level the CLIP LED warns you to reduce the gain with the MIC GAIN control, so as to avoid
distortion caused by overloading. During normal operation, the LED should not light up at all.
5
With the PHASE REV. switch the input signal is reversed in phase by 180°. This function is available
both in MIC and LINE modes.
6
When the high-pass filter is switched on (LO CUT switch pressed), the FREQUENCY control defines
the filter’s cut-off frequency. With a setting range from 12 to 320 Hz the filter’s main task is to eliminate
bottom-end rumble noise, etc.
7
The LO CUT switch activates/deactivates the high-pass filter.
The following 6 control elements refer to the parametric equalizer only.
8
The FREQUENCY control is used to select the frequency to be modified. Please note that the frequency
range can be lowered/raised with the switches x0.1 and x10. In this way, you can process the entire
audio range between 10 Hz and 20 kHz. With both switches out, the FREQUENCY control can be
swept over a range from 100 Hz to 2 kHz.