Table of Events and Alarms
A-2
Cajun A500 ATM Switch User Guide
TFTP server not set
Status Only: No Action Required
--
TFTP server set
Status Only: No Action Required
--
System alarms cleared
Status Only: No Action Required
--
New notifyrc processed
Status Only: No Action Required
--
New SNMP files processed
Status Only: No Action Required
--
Event log cleared
Status Only: No Action Required
--
SPF bringing down neighbor due to
time out
Status Only: No Action Required
--
Table 1-2. Alarms
Alarms
Possible Cause/Remedy
Number
Failed to fetch configuration files
-No TFTP server set:
>Use
>Use
tftp setserver
to set address.
-TFTP files do not reside on TFTP server.
>Connection problems to tftp server:
>Verify server connection.
>Connection problems to tftp server:
>Verify server connection.
0
No IP address set at boot
-No Cajun A500 IP address set.
>Use
>Use
admin address
and reboot.
1
IP configuration problems detected at
boot
-Address not compatible with mask:
-Default gateway set to different subnet than IP
-Default gateway set to different subnet than IP
address.
-No IP mask set:
>Use
-No IP mask set:
>Use
status
command and then set correctly.
2
Power Supply failure
-An active supply has been unplugged/shut off:
>Check power to supply.
-One of the active supplies has been removed from
>Check power to supply.
-One of the active supplies has been removed from
the chassis:
>Insert power supply.
-One of the active power supplies has failed:
>Replace faulty supply.
>Insert power supply.
-One of the active power supplies has failed:
>Replace faulty supply.
3
Fan failure
-A system fan is no longer functional:
>Inspect the fans and replace faulty units.
>Inspect the fans and replace faulty units.
4
Check voltage
-System voltage is not within acceptable range:
>Use
>Use
show system configuration
command to
inspect voltage. Connect unit to conforming outlet.
5
Table 1-1. Events
Events
Possible Cause/Remedy
Number