`~àìå=mRRMLmUUM=pïáíÅÜ=^qj=`if=réäáåâ=oÉÑÉêÉåÅÉ=dìáÇÉI=sÉêëáçå=NKN==
`~àìå=^qj=réäáåâ=`if=`çãã~åÇë
==============NJPV
ëÉí=äÉÅ=EíêáÖÖÉêJÅçìåíF
`çãã~åÇ=jçÇÉ
Configuration
aÉëÅêáéíáçå
Set the count to determine the frame rate at which the LEC attempts 
to resolve an unknown destination MAC address to a data direct 
VCC.
* Note:  You must disable a LEC each time you make a change to 
the configuration. After you make configuration 
changes, you must enable the LEC in order for the 
changes to take effect.
póåí~ñ
set lec <lecID> trigger-count
<trigger-count-value>
q~ÄäÉ=NJPNK==m~ê~ãÉíÉêëI=hÉóïçêÇëI=^êÖìãÉåíë
p~ãéäÉ=lìíéìí
This example sets the trigger count for LEC 2 to a programmed time 
interval of 15. 
ATM(configure)# set lec 2 disable
LEC 2 has been disabled
ATM(configure)# set lec 2 trigger-count 15
LE ARP Trigger Count 15 has been set for LEC 2
ATM(configure)# set lec 2 enable
LEC 2 has been enabled
Name
Definition
lecID
The LEC identifier. The range of values is: 
Minimum = 1, Maximum = 128.
trigger-count-value
The LE ARP trigger count measured in 
seconds. The range of values is: Minimum = 1, 
Maximum = 20.