Avaya 3749 사용자 가이드

다운로드
페이지 115
 
12
Avaya 374x DECT Telephones - User Guide
11/2010
Headset in ATEX/IECEx classified areas
In hazardous areas, it is only permitted to use the headset adapter for Peltor headset (art. no.: 
660281) in combination with an ATEX/IECEx classified Peltor headset. The headset must be 
compatible with the output parameters of the headset connector as follows:
U
o
 = 4.2 V
I
o
 = 169 mA
P
o
 = 583 mW
C
o
 = 2.2 µF
L
o
 = 2.2 µH 
Sensitive Electronic Environment (EU/EFTA only)
Only use this product in countries where the appropriate authorities have given their 
authorisation.
The CE symbol on the product certifies its conformity with the technical guidelines concerning 
user safety and electro-magnetic compatibility valid at the time of approval; in accordance with 
European directive No. 1999/05/EC.
The products Avaya 374x DECT Telephones comply with IP65 according to IEC 529 / EN 60 
529.
Any radio-based equipment can potentially cause interference with other equipment and can be 
interfered from other equipment. This also applies for DECT equipment. However due to the 
very low transmission power level the changes for interference are very small. Research proves 
that operational DECT telephones normally don't influence electronic equipment however some 
precautions must be taken into account for sensitive electronic equipment e.g. sensitive 
laboratory equipment. When DECT telephones operate in straight nearness of sensitive 
electronic equipment incidental influence can appear. You are advised not to place the DECT 
telephone on or close (less then 10 cm) to this kind of equipment, even in standby mode.
Regulatory Compliance Statements (EU/EFTA only)
Permission and Conformity
We, Avaya Inc., declare that the product line DECT R4 concurs with the basic requirements and 
other relevant provisions of EU Directive 1999/5/EU concerning radio equipment and 
telecommunications terminal equipment and the mutual recognition of their conformity.