Avaya 6402D 사용자 가이드

다운로드
페이지 178
9-4
PORT PACKS: DEFINITY GENERIC 2 WITH UNIVERSAL MODULES
TABLE 9-3 Voice Terminal Loop Ranges
Distance (Ft)
Terminal Type
Comments
24 AWG
26 AWG
Analog
500/2500
20000
13000
On-premises or out-of-building —
same premises (TN742, TN769).
500/2500
3100
2000
On-premises only — no bridging
terminals without adjuncts
(TN742).
710X
15200
10000
Hybrid
730X
1000
750
Without adjunct power
2000
2000
With adjunct power
Digital
740X
3000
2200
On premises
2400
1300
Out-of-building same premises
B R I
750X
1900
1600
Adjunct Power required on all
terminals
All 750X terminals require a
terminating resistor. These figures
assume the resistor is installed
within 33’ (IOM) of the terminals.
DCP REPEATERS
Basic guidelines for DCP repeaters are the same for DEFINITY Generic 2 with universal modules as
they are for System 85 and DEFINITY Generic 2 with traditional modules. See chapter 4,
Portpacks/DCP Repeaters: System 85 and DEFINITY Generic 2 with Traditional Modules 
for more
detailed information.