Chapter 7: Technical Description
DEFINITY
 Communications System
DEFINITY High Speed Link
Page  7-2
User´s Guide
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
Dialing Methods
d
Manual stored number
d
DTR stored number
d
Hotline
d
RS-366/RS-232
Memory
d
Non-volatile memory for storing options and four telephone
numbers
ffffffffffffffffffffffffffffffffffffffffffff
AC POWER
AC Voltage
d
104 to 129 volts
Frequency
d
57 to 63 Hz
Power Consumption
d
9 watts
ffffffffffffffffffffffffffffffffffffffffffff
DC POWER
The HSL is powered by an external power supply.  Connection to
the power supply uses a six position male connector with one pin
removed for polarization.  The power supply must provide +5.0
vdc, and 
±
12.0 vdc relative to the signal ground lead.  The 5 volt
supply must provide at least 1.50 amp with a voltage tolerance of
±
5 percent.  The 12 volt circuits must provide at least 0.10 amp
each with a voltage tolerance of 
±
10 percent.  The power supply
also provides a separate green wire ground connection.  The green
wire ground lead is permanently connected to the signal ground
inside the HSL.
ffffffffffffffffffffffffffffffffffffffffffff
ENVIRONMENTAL
REQUIREMENTS
Operating Temperature
d
40 to 120 degrees F (5 to 49 degrees C)
Relative humidity
d
5 to 95 percent below 84 degrees F, less than 168 grains of
water vapor per pound of dry air above 84 degrees F
ffffffffffffffffffffffffffffffffffffffffffff
REGISTRATION
FCC:  Part 15, sub-part B approved