Epson 5600p 참조 가이드

다운로드
페이지 20
ESC/VP Level 6 Serial Communication Manual (Abridged Edition) 
9 of 20
6. CONTROL CODE
00  SPECIAL CONTROL
Command
structure
Type
Apply
Reply
STX
Size
Attribu
te
From
To
Group
Item
Param
eter
Check-
sum
STX
Size
Attribu
te
From
To
Group
Item
Param
eter
Check-
sum
03 : Power
Controls the projector power and gets the present power state.
<In the case of a power on setup of EMP-7600/5600>
Set
1B
07
01
--
00
03
01
F4
1B
06
81
C1
--
00
03
--
CS
<In cases other than a power on setup of EMP-7600/5600, and the case of EMP-8100/9100/8150/7700>
[Parameter]
Data relating to the power states.
0x00: PowerOFF
0x01: PowerON
0x02: Suspend
0x10: During Startup
0x11: Cool down
0x20: System fault
* Although setting 0x02 and later in parameter and sending command to the projector, returns NG 
in replay. 0x02 and later are available just for informing from the projector. 
Set
1D
0009
01
01
00
03
00
01
CS
1D
0008
000A
81
C1
10
00
03
--
PARA
CS
Get
1D
0008
02
01
00
03
--
CS
1D
0009
000A
82
C2
10
00
03
PARA
CS
06 : Communication rate
Controls the communication rate.
[Parameter]
Data relating to communication rate.
<For EMP-8100/9100/8150/7700>
0x00: 9600bps
0x01: 19200bps
0x02: 38400bps
0x03: 57600bps
<For EMP-7600/5600>
0x00: 9600bps
0x01: 19200bps
0x02: 38400bps
Set
1D
0009
01
01
00
06
PARA
CS
1D
0008
000A
81
C1
10
00
06
--
PARA
CS
Get
1D
0008
02
01
00
06
--
CS
1D
0009
000A
82
C2
10
00
06
PARA
CS
Initialize
1D
0008
03
01
00
06
--
CS
1D
0009
000A
83
C3
10
00
06
PARA
CS
09 : Lamp Hour
Gets the present lamp hour.
[Parameter]
Returns the present lamp hour (in hours) (2 bytes)
Get
1D
0008
02
01
00
09
--
CS
1D
000A
000A
82
C2
10
00
09
PARA
CS
12 : Error information
Gets and reports projector error information.
[Parameter]
Projector error information
The following data is set with an OR:
0x00: No error or error is cancelled.
0x01: Fan problem
0x04: Internal temperature is abnormally high.
0x08: Lamp life expectancy is closed to end.
0x20: Lamp problem
0x40: Other failures
0x80: Stack failure (EMP-8100/8150/9100 only)
Set
1D
0009
01
01
00
12
--
CS
1D
0008
000A
81
C1
10
00
12
--
PARA
CS
Get
1D
0008
02
01
00
12
--
CS
1D
0009
000A
82
C2
10
00
12
PARA
CS
}