Setting the DIP Switches (to Adjust Output Gain)
1.  Using  the  Compatibility  Matrix  in  Appendix  A,  set  the  DIP  switches 
in  the  Digital  Module  to  the  correct  position.  If  your  PBX  System 
indicates  a  setting  which  requires  a  custom  setting,  you  will  have 
to  follow  “The  Gain  Adjustment  Procedure”  to  set  your  switches.
2. Turn ON the  Aura SoHo™ Conference Phone by pressing the � button.
3. Press the CONF button until the backlight on the keypad flashes 3 times.
4. Remove the handset from the PBX phone cradle.
5. Dial another PBX phone in the office using the PBX phone keypad. Begin 
speaking to check that the receiving side can hear you clearly. If the sound 
volume is ok, proceed to “Making a Call”. If the sound volume is too low, you 
will need to adjust the dip switches on the bottom of the Digital Module, 
from left to right; make sure to keep Switch 1 ON. 
The Gain Adjustment procedure
Since all PBX Systems have different gain levels, you will have to experiment 
to find the setting that best fits your system. Once you have achieved a 
setting  that  allows  for  the  best  output  gain,  leave  the  switches  in  that 
position.
1. Set Switches 2, 3, 4 to the OFF position. This is the default gain of -3 dB.
2. Turn the Aura SoHo™ Conference Phone over and test the volume level.  
To increase the volume, access the bottom of the Digital Module again.
3. Set Switch 2 to the ON position; Switches 3 and 4 will be OFF. This will 
increase the output level to 0 dB. Test the volume level again.
4.  To increase the level again, set Switch 3 to the ON position. Switches 2 
and 4 will be in the OFF position. This increases the output level to 6 dB. 
5. To increase the output level to 9 dB, set Switch 4 to the ON position, and 
Switches 2 and 3 to the OFF position.
6. The maximum level is 15 dB. Set all the Switches to the ON position.
When you have the correct level set, press the FLASH button on the on the Aura 
SoHo™ Conference Phone’s keypad. This will end the Gain Adjustment Mode. 
To verify that you have set the correct level, make a test phone call. If the 
level is not correct, repeat the Gain Adjustment procedure until you reach 
the proper output level. Remember you will have to press the CONF button 
Location of Switches
Switch 1
ON