OrderinG inFOrmatiOn
Page 4
800-675-8410 • 949-250-6510  •  www.omnitron-systems.com  •  info@omnitron-systems.com  •  140 Technology Dr. Irvine, CA 92618
iConverter
 10/100M 
Trademarks are owned by their respective companies. iConverter and NetOutlook are registered trademarks of Omnitron Systems Technology, Inc.
©2010 Omnitron Systems Technology, Inc.  All rights reserved.  Specifications subject to change without notice.  
091-18900-001J 
9/10
8 9 x x - x - x x
<Blank> Standard Operating Temperature Range Model
W
Z
Wide
Temperature Range Model
Operating
Extended Operating Temperature Range Model
0 For Dual-Fiber: 5km
For SFP Model
1 For Single-Fiber: 20km
For Dual-Fiber: 30km
2 For Single-Fiber: 40km
For Dual-Fiber: 60km
3 For Dual-Fiber: 120km
<Blank> Plug-In Module
A
Tabletop with External US AC Power Supply
B
Tabletop
Universal AC Power Supply
with External
C
Tabletop with DC Terminal Power
D
Wall-Mount
External US AC Power Supply
with
E
Wall-Mount
External Universal AC Power Supply
with
F
Wall-Mount
DC Terminal Power
with
00
ST Connector
Dual-Fiber
Multimode
01
ST Connector
Dual-Fiber
Single-Mode
02 Dual-Fiber SC Connector Multimode
03 Dual-Fiber SC Connector Single-Mode
04 Dual-Fiber MT-RJ Connector Multimode
05 Dual-Fiber MT-RJ Connector Single-Mode
07 Dual-Fiber LC Connector Single-Mode
10 Single-Fiber SC Connector Single-Mode
11 Single-Fiber SC Connector Single-Mode
19 Small Form Pluggable (SFP) Model
Fiber Type /
Dual Fiber or
Single-Fiber
Distance
Connector Types
Tx
Lambda
 [nm]
Rx
Lambda
[nm]
Min. Tx
Power
[dBm]
Max. Tx
Power
[dBm]
Min. Rx
Sense
[dBm]
Max. Rx
Power
[dBm]
Link
Budget
ST
SC
MT-RJ
LC
SFP
SFP
-
-
-
-
-
8919-0
-
-
-
-
-
-
-
MM/DF
5km
8900-0
8902-0
8904-0
-
-
1310
1310
-24
-14
-31
-14
7
SM/DF
30km
8901-1
8903-1
8905-1 8907-1
-
1310
1310
-15
-8
-31
-8
16
SM/DF
60km
8901-2
8903-2
-
8907-2
-
1310
1310
-5
0
-31
-3*
26
SM/DF
120km
-
8903-3
-
8907-3
-
1550
1550
-5
0
-31
-3*
26
SM/SF
20km
-
8910-1
-
-
-
1310
1550
-15
-5
-30
-3
15
SM/SF
40km
-
8910-2
-
-
-
1310
1550
-8
0
-30
-3*
22
SM/SF
20km
-
8911-1
-
-
-
1550
1310
-15
-5
-30
-3
15
SM/SF
40km
-
8911-2
-
-
-
1550
1310
-8
0
-30
-3*
22
 When using single-fiber (SF) media converter models, the Tx wavelength on one end has to match the Rx wavelength on the other.
 
*A minimum of 3dB of attenuation is required for these models.  When ordering a Wide Temperature model, add a "W" to the end of