Omnitron iConverter 10/100 8381-1 전단

제품 코드
8381-1
다운로드
페이지 2
Ordering inFOrmatiOn
Page 2
800-675-8410 • 949-250-6510  •  www.omnitron-systems.com  •  info@omnitron-systems.com  •  140 Technology Dr. Irvine, CA 92618
iConverter
 10/100 
© 2010 Omnitron Systems Technology, Inc.  All rights reserved.  
iConverter
 and 
NetOutlook
 are Registered Trademarks of Omnitron Systems Technology, Inc.  
Trademarks are owned by their respective companies.  Specifications are subject to change without notice.
091-18380-007J 
9]/10
speciFicatiOns
management
Management is accomplished by using a Network Management 
Module (NMM2) or a media converter with integrated management 
(such as an iConverter 10/100M2) that provides monitoring,  
remote configuration and trap notification.  The management 
module can be accessed via SNMP, Telnet and via a serial 
port.  The  SNMP-based  management  is  accomplished  via 
Omnitron’s intuitive, graphic-oriented NetOutlook management 
software or third party SNMP management software, while the 
Telnet and the serial interfaces have an easy-to-use, menu-
driven interface.
Some of the real-time 10/100 parameters that can be monitored 
include power, link and data receive status. Other parameters 
include  module  type  and  model,  hardware  and  software 
revisions, serial numbers, and an user-defined identifier.
The  user  can  override  the  10/100  module’s  physical  
DIP-switch settings using SNMP or Telnet to remotely configure 
DIP-switch-selectable parameters such as auto-negotiation, 
Half/Full-Duplex, Link Mode selection, and Ethernet Backplane 
selection.
In  addition  to  all  standard  iConverter  SNMP  traps  such  as 
module  insertion  and  removal,  the  10/100  modules  can 
generate  traps  on  port  state  changes  including  link-up  and 
link-down.  Trap monitoring of specific events can be selectively 
enabled or disabled by the network administrator.
Model Type
10/100
Protocols
100BASE-FX, 10BASE-T,
or 100BASE-TX
UTP Connectors
RJ-45
Fiber Connectors
SC, ST, LC, MT-RJ, Single-Fiber SC
Controls
UTP X-over, LS/LP, RFD, Auto/Man,
10/100, FDX/HDX
LED Displays
Power, FO link, UTP link, Auto,
 UTP FDX/HDX, F/O FDX/HDX, 10, 100
Dimensions
W:0.85" x D:4.5" x H:2.8"
Weight
8 oz.
Compliance
UL, CE, FCC Class A, NEBS Level 3
Power Requirement
0.95A @ 3.3VDC (typical)
Temperature
             Standard:    0 to 50º C
                   Wide:    -40 to 60º C
               Storage:    -40 to 80º C
Humidity
5 to 95% (non-condensing)
Altitude
-100m to 4000m
MTBF (hrs)
1,050,000
Model Type
Fiber  /
Media
Type
Distances
Connector Types
Tx
Wavelength
(nm)
Rx
Wavelength
(nm)
Min. Tx
Power
(dBm)
Max. Tx
Power
(dBm)
Min. Rx
Sensitivity
(dBm)
Max. Rx
Sensitivity
(dBm)
Link
Budget
(dBm)
ST
SC
MT-RJ
LC
10/100
Dual Fiber
MM
2km
8380-5
8382-5
-
-
850
850
-23
-12
-31
-12
8
MM
5km
8380-0
8382-0
8384-0 8386-0
1310
1310
-24
-14
-31
-14
7
SM
30km
8381-1
8383-1
8385-1 8387-1
1310
1310
-15
-8
-31
-8
16
SM
60km
8381-2
8383-2
-
8387-2
1310
1310
-5
0
-31
-3*
26
SM
120km
-
8383-3
-
8387-3
1550
1550
-5
0
-31
-3*
26
10/100
Single-Fiber
SM
20km
-
8390-1
-
-
1310
1550
-15
-5
-30
-3
15
SM
40km
-
8390-2
-
-
1310
1550
-8
0
-30
-3*
22
SM
60km
-
8390-3
-
-
1310
1550
-5
0
-31
-3*
26
SM
20km
-
8391-1
-
-
1550
1310
-15
-5
-30
-3
15
SM
40km
-
8391-2
-
-
1550
1310
-8
0
-30
-3*
22
SM
60km
-
8391-3
-
-
1550
1310
-5
0
-31
-3*
26
 For wide temperature (-40 to 60º
 
C), add a "W" to the end of the model number. Consult factory for extended temperature (-40 to +75º
 
C) models and other fiber
 configurations.  When using single-fiber (SF) media converter models, the Tx wavelength on one end has to match the Rx wavelength on the other.
 *A minimum of 3dB of attenuation is required for these models.