Canon XF100 매뉴얼

다운로드
페이지 183
75
b Synchronizing with an External Device
b Synchronizing with an External Device
Using genlock synchronization, you can synchronize this camcorder's video signal to that of an external video 
device. Similarly, using an external time code signal, you can synchronize this camcorder's time code to the 
external signal. Using the external time code signal with multiple cameras allows you to set up a multi-camera 
recording. You can also output the time code signal from this camcorder to achieve the same result. If you 
output the time code from the HD/SD SDI terminal to an editing device, the editor can create video with the 
same time code.
Connecting an External Device
When synchronizing the camcorder to an external signal, input a reference 
video signal* or a time code signal through the GENLOCK/TC terminal. The 
GENLOCK/TC terminal acts as both a Genlock and time code terminal. 
When using a time code signal, set the terminal to input or output in 
advance (see below).
* For the reference video signal, you can use an analog blackburst or tri-level signal.
Using a Reference Video Signal 
(Genlock Synchronization)
When a reference sync signal (analog blackburst or tri-level signal) is input 
through the GENLOCK/TC terminal, the phases of the camcorder's V and 
H sync will automatically be synchronized to it. The phase difference 
between the external Genlock signal and the camcorder is initially set to 0. 
The H phase can be adjusted within the range of approximately ±0.4 H (HD 
equivalent).
1 Open the [Genlock/TC Term.] submenu.
[J Other Functions] 
 [Genlock/TC Term.]
2 Select [Gen/TC In] and then press SET.
3 Open the [Genlock Adjust.] submenu.
[J Other Functions] 
 [Genlock Adjust.]
4 Adjust the phase to the desired level and then press SET.
• You can adjust the phase within -1023 to 1023. When selecting more 
than 999 or less than -999, set the first field to 10 or -10, respectively.
Using a Time Code Signal
An external SMPTE-standard LTC timing signal received from the 
GENLOCK/TC terminal will be recorded as the time code. The user bit of 
the external timing signal can also be recorded. Before connecting the 
device, set the GENLOCK/TC terminal to input. Also, you must set the 
running mode of the time code to [Free Run] (0 71).