ASUS RS720-E7/RS12 사용자 설명서

다운로드
페이지 188
華碩 RS720-E7/RS12、RS720-E7/RS12-E 系列使用手冊
6-19
3.  當出現提示時,按下 <空白> 鍵並從 Consistency Check? 的對話框中選擇 
Yes,然後按下 <Enter> 鍵。
這時畫面中會以百分比顯示完成的進度。
Management Menu
Configure
 
Initialize 
Objects 
Rebuild 
Check Consistency
Virtual Drive(s) Configured
LD    RAID    Size    #Stripes    StripSz   Status
0      10   154494MB     4        64 KB     ONLINE
Virtual Drives
Virtual Drive 0
Consistency Check?
Yes
No
Select VD
LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010
BIOS Version   A.10.09231523R
SPACE-(De)Select,   F10-Check Consistency
Management Menu
Configure
 
Initialize
 
Objects 
Rebuild 
Check Consistency
Virtual Drive(s) Configured
LD    RAID    Size    #Stripes    StripSz   Status
0      10   154494MB     4        64 KB     ONLINE
Virtual Drives
Virtual Drive 0
CC Under Process
VD 0 Consistency Check. Press Esc to Abort.
¦ 85 % Completed
The Data On The Drives Is Inconsistency. Repair Done!
LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010
BIOS Version   A.10.09231523R
SPACE-(De)Select,   F10-Check Consistency
4.  當正在進行檢查硬碟資料一致性時,按下  <Esc>  鍵則會顯示以下的功能
選項。
 
·Stop 
 停止檢查的動作。程式會儲存硬碟所檢查的百分比。當您
重新進行檢查時,就會從儲存的百分比處繼續進行檢查的
動作。
 
·Continue 
繼續檢查硬碟資料。
 
·Abort 
 放棄檢查一致性的動作。當您重新進行檢查時,就會從 
0% 開始重新檢查。
5.  當完成檢查硬碟資料一致性時,按任何一鍵繼續。