Canon KP Series 브로셔
![Canon](https://files.manualsbrain.com/attachments/4b6818c07b947b910f8cfb49338c2c63bdefaee1/common/fit/150/50/61ea34cb812b6780fe3b16f0b9221bd2f7635c65cee2473b66396d8b72cd/brand_logo.png)
CANON Digital Galvano Scanner System
KP-1SM Series + GC-251
Users Manual 1.00
16
2.7.1 RS-232C command input
RS-232C command input allows the following:
• Operation
setting
• Parameter
setting
• Error
processing
• Status
check
(For details, see 7, “Commands.”)
If position data send by high-speed serial communication is disabled, RS-232C command input is
enough for the following:
• Step
movement
• Raster
scan
(Continuous
oscillation of a certain angle at a fixed frequency)
(Communication specifications)
Wiring Cross
wiring
Communication rate
38400 bps
Data length
8 bits
Stop bit
1
Parity None
Data format
ASCII code
Delimiter code
LF (0x0a) or CR (0x0d)