 Controller-Managed Access Points
380
ProSAFE Wireless Controller 
c.  Reconfigure the static IP address setting and the VLAN settings or reenable the 
DHCP client.
If you cannot connect to the access point, its IP address might be the factory default 
IP address.
The access point’s IP address is reset to the factory default IP address. Do the 
following:
a.  Determine the factory default IP address for the model access point.
b.  Configure a computer with a static IP address in the same subnet as the factory 
default IP address of your model access point and a subnet mask of 
255.255.255.0.
c.  Use an Ethernet cable to connect the computer to the access point.
d.  Log back in to the access point using the factory default IP address of your 
model access point.
e.  Enter the user name and password.
The user name is admin. The default password is password. The user name and 
password are case-sensitive.
f.  Select Configuration > Upgrade > Firmware Upgrade.
Access Point Model
Factory Default IP Address
WAC740
192.168.0.160
WAC730
192.168.0.100
WAC720
192.168.0.100
WN370
192.168.0.160
WND930
192.168.0.100
WNDAP660
192.168.0.100
WNDAP620
192.168.0.100
WNDAP380R
Not applicable
1
1. The WNDAP380R does not provide a web
management interface and a default IP address.
The WNDAP380R can be managed only by a
wireless controller in a network with a DHCP server.
WNDAP360
192.168.0.100
WNDAP350
192.168.0.237
WNAP320
192.168.0.100
WNAP210v2