Netgear M5300-52G-POE+ (GSM7252PSv1h2) - ProSAFE 48+4 L2+ POE Stackable Managed Switch 소프트웨어 가이드

다운로드
페이지 764
Chassis and Stacking 
170
M6100, M5300, and M7100 Series Managed Switches 
The default admin user name is admin and the default admin password is blank, that is, 
do not enter a password.
6. 
Click the Login button. 
The web management interface menu displays.
7. 
Select System > Chassis > Advanced > Chassis Power Configuration
The Chassis Power Configuration screen displays.
Scroll down to the Power Module section..
The following table describes the nonconfigurable Power Module data that is displayed.
View EPS Power Modules and EPS Ports
To display EPS ports:
1. 
Prepare your computer with a static IP address in the 169.254.100.0 subnet, for 
example, 169.254.100.201.
2. 
Connect an Ethernet cable from an Ethernet port on your computer to an Ethernet port on 
the switch.
3. 
Launch a web browser.
4. 
Enter the IP address of the switch in the web browser address field.
The default IP address of the switch is 169.254.100.100. 
Table 65.  Power Modules 
 
Field
Description
Slot
Power module number counted from left to right.
Type
Power module type. Valid values are Fixed and Removable.
State
Power module state. Possible states are as follows:
• 
Operational
• 
Failed
• 
Not Present
• 
Not Powered
• 
Not Applicable
AC
Power module input voltage category in volts. Possible values are 
110V
220V, and N/AN/A specifies that power source input voltage 
cannot be obtained.