  Appendix B:  Configuration Examples
 
   
|
     
307
GS752TXS Smart Switch Software Administration Manual 
kind outside the Region, in other words connectivity within the region is independent of 
external connectivity.
MSTP Example Configuration
This example shows how to create an MSTP instance from the GS752TXS switch. The 
example network has three different GS752TXS switches that serve different locations in the 
network. In this example, ports g1–g5 are connected to host stations, so those links are not 
subject to network loops. Ports g6–g8 are connected across switches 1, 2, and 3.
Ports g1-g5
Switch 1
Connected to Hosts
Root Bridge
Switch 2
Switch 3
Ports g1-g5
Connected to Hosts
Ports g1-g5
Connected to Hosts
Ports g6-g8
Connected to Switch 2 and 3
Ports g6-g8
Connected to Switch 1 and 2
 
Perform the following procedures on each switch to configure MSTP:
1. 
Use the VLAN Configuration screen to create VLANs 300 and 500 (see 
2. 
Use the VLAN Membership screen to include ports g1–g8 as tagged (T) or untagged (U) 
members of VLAN 300 and VLAN 500 (see 
3. 
110).
Use the default values for the rest of the STP configuration settings. By default, the STP 
Operation Mode is MSTP and the Configuration Name is the switch MAC address.
4. 
From the CST Configuration screen, set the Bridge Priority value for each of the three 
switches to force Switch 1 to be the root bridge:
•     
Switch 1: 4096
•     
Switch 2: 12288
•     
Switch 3: 20480