Configure SNMP
292
ProSAFE FS526Tv2, FS726Tv2, and FS728TLP Smart Switches
Remove an SNMP Trap Receiver
To remove an SNMP trap receiver:
1.
Select System > SNMP > SNMP V1/V2 > Trap Configuration.
The Trap Configuration screen displays.
2.
In the Trap Configuration table, select the check box to the left of the trap receiver that you
want to remove.
want to remove.
3.
Click the Delete button.
The trap receiver is removed from the Trap Configuration table.
Configure the SNMP Trap Flags
If you configure one or more trap communities, you also need to specify which SNMP traps
the smart switch can generate and send. When the smart switch detects a condition that is
identified by an active trap, it sends a trap to the trap communities.
the smart switch can generate and send. When the smart switch detects a condition that is
identified by an active trap, it sends a trap to the trap communities.
You can configure some traps on the Trap Flags screen and other traps on screens that let
you configure the features that the traps are associated with. The smart switch supports the
following traps:
you configure the features that the traps are associated with. The smart switch supports the
following traps:
•
Cold start trap
•
Link up/down trap
•
Authentication failure trap
•
Bridge new root trap
•
Bridge topology change trap
•
RMON alarm trap
•
PoE port on/off trap
•
PoE power usage on/off trap
•
LLDP remote tables change trap
•
LLDP-MED topology change trap
•
Learn limit violation trap
To configure the trap flags:
1.
Select System > SNMP > SNMP V1/V2 > Trap Flags.