Netgear FS526Tv2 - 24-Port Smart Switch with Gigabit Ports 사용자 가이드
Configure Basic System Settings
49
ProSAFE FS526Tv2, FS726Tv2, and FS728TLP Smart Switches
5.
(Optional) Click the Refresh button.
The screen refreshes to display the most current data.
Change an SNTP Server
To change the settings for an SNTP server:
1.
Select System > Management > Time > SNTP Server Configuration.
The SNTP Server Configuration screen displays.
2.
In the SNTP Server Configuration table, select the check box next to the SNTP server for
which you want to change the settings.
which you want to change the settings.
3.
Change the settings.
You cannot change the server type or IP address.
4.
Click the Apply button.
The settings are saved.
Remove an SNTP Server
To remove an SNTP server:
1.
Select System > Management > Time > SNTP Server Configuration.
The SNTP Server Configuration screen displays.
2.
In the SNTP Server Configuration table, select the check box next to the SNTP server that
you want to remove.
you want to remove.
3.
Click the Delete button.
The SNTP server is removed from the SNTP Server Configuration table and the SNTP
Server Status table.
Server Status table.
Configure the Time Settings Through SNTP
Use the Time Configuration screen to enable SNTP and view the global SNTP status. Before
you can enable SNTP, you first need to configure an SNTP server (see
you can enable SNTP, you first need to configure an SNTP server (see
47).
To configure the time through an SNTP server:
1.
Select System > Management > Time > SNTP Global Configuration.
Requests
The number of SNTP requests that were sent to the SNTP server since the smart
switch started.
switch started.
Failed Requests
The number of failed SNTP requests that were sent to the SNTP server since the
smart switch started.
smart switch started.
Field
Description