Netgear M5300-52G (GSM7252S) - ProSAFE 48-port Gigabit L2+ Managed Stackable Switch 소프트웨어 가이드
Monitor the System
698
M6100, M5300, and M7100 Series Managed Switches
A log that is disabled does not log messages.
8.
Select the Admin Mode Disable or Enable radio button.
9.
ln the Behavior list, select the severity level.
A log records messages equal to or above a configured severity threshold. These
severity levels are available:
•
Emergency (0
). The system is unusable
•
Alert (1)
. Action must be taken immediately
•
Critical (2)
. Critical conditions
•
Error (3)
. Error conditions
•
Warning (4)
. Warning conditions
•
Notice (5)
. Normal but significant conditions
•
Informational (6)
. Informational messages
•
Debug (7)
. Debug-level messages
To refresh the screen with the latest information on the switch, click the Update button.
Format of the Messages
•
Total number of messages: Number of persistent log messages displayed on the
switch.
switch.
•
<15>Aug 24 05:34:05 STK0 MSTP[2110]: mspt_api.c(318) 237 %% Interface 12
transitioned to root state on message age timer expiry
transitioned to root state on message age timer expiry
This example indicates a user-level message (1) with severity 7 (debug) on a system that
is not a chassis and generated by component MSTP running in thread ID 2110 on Aug 24
05:34:05 by line 318 of file mstp_api.c. This is the 237th message logged. Messages
logged to a collector or relay through syslog use a format identical to the previous
message.
is not a chassis and generated by component MSTP running in thread ID 2110 on Aug 24
05:34:05 by line 318 of file mstp_api.c. This is the 237th message logged. Messages
logged to a collector or relay through syslog use a format identical to the previous
message.