Netgear GSM7224v2 - 24-Port Layer 2 Managed Gigabit Switch 사용자 설명서

다운로드
페이지 628
  Chapter 2.  Configuring System Information
 
   
|
     
87
ProSafe® Gigabit L3 Managed Stackable Switches Software Administration Manual 
PoE Configuration
Use the PoE Configuration page to view global PoE power information and to configure PoE 
SNMP trap settings.
To display this page, click System 
 PoE 
 Basic 
 PoE Configuration. A screen similar to the 
following displays.
1. 
Unit - Displays the Current PoE Unit. You can change the PoE Unit by selecting another 
unit ID listed here.
2. 
Use System Usage Threshold to set a threshold level at which a trap is sent if consumed 
power is greater than threshold power.
3. 
Use Power Management Mode to describe or control the power management algorithm 
used by the PSE to deliver power to the requesting PDs. "Static" value means that power 
allocated for each port depends on the type of power threshold configured on the port. 
"Dynamic" value means that power consumption of each port is measured and calculated in 
real-time.
4. 
Use Auto Reset Mode to specify Enable or Disable. When set to "Enable", the PSE port is 
reset without administrator intervention whenever a fault condition occurs. When set to 
"Disable", the administrator has to reset the PSE port whenever a fault condition is detected.
5. 
Use Traps to enable or disable activation of PoE traps by selecting the corresponding check 
box. The factory default is enabled.
Table 3.  
Field
Definition
Firmware Version
Version of the PoE controller's firmware image.
Power Status
Indicates the power status.