Netgear APS250W – Power Supply Unit 250W AC 설치 가이드

다운로드
페이지 2
December 2015
NETGEAR, Inc.
350 East Plumeria Drive
San Jose, CA 95134, USA
© NETGEAR, Inc., NETGEAR and the NETGEAR Logo are trademarks of NETGEAR, Inc. Any non‑NETGEAR 
trademarks are used for reference purposes only.
3.  Insert the replacement PSU into the power module bay, and gently push 
the PSU into the bay until the latch locks.
CAUTION: 
When inserting the PSU, do not use unnecessary force. 
Doing so can damage the connectors on the back of the PSU and on the 
midplane.
4.  Connect the end of the power cord to the power receptacle on the PSU.
5.  Plug the AC power cord into a power source such as a wall socket or 
power strip.
When you apply power, both the AC OK LED on the PSU and the 
switch’s Power LED that is associated with the power supply bay light. 
If these LEDs do not light, make sure that the power cord is plugged in 
correctly and that the power source is good.
Power Supply Unit Technical Specifications
The following table provides the technical specifications for the PSUs.
Specification
APS150W
APS250W
APS550W
APS1000W
AC input
100–27V ~3A 
50–60 Hz or 
200–240V ~1.5A 
50–60 Hz
100–240V 
~3.5–2A 
50–60 Hz
100–240V 
~9–4A 
50–60 Hz
100–127V ~9.9A 
50–60 Hz or 
200–240V ~7.8A 
50–60 Hz
DC output
+12V 12.5A
+12V 20A 
+12 VSB 1A
+54V 10.95A 
+12 VSB 2.08A
56V 12.12A 
+12 VSB 1.8A 
@ 100–127V
56V 17.35A  
+12 VSB 2.4A  
@ 200–240V
Dimensions 
(H x W x D)
1.5 x 2.0 x 7.3 in.  
(39 x 50.5 x 
185 mm)
1.5 x 2.9 x 7.3 in.
(39 x 74 x 185 mm)
1.64 x 3.6 x 8.65 in. 
(39.3 x 86.36 x 
207.56 mm)
1.64 x 3.6 x 8.65 in. 
(39.3 x 86.36 x 
207.56 mm)
Operating 
temperature
–5 to 50ºC  
(23 to 122ºF)
0 to 50ºC 
(32 to 122ºF)
0 to 55ºC (32 to 131ºF)
Specification
APS150W
APS250W
APS550W
APS1000W
Operating relative 
humidity
Up to 95%  
noncondensing
5% to 95% noncondensing
Operating altitude 
level
Below 5,000 m 
above sea level
Below 3,000 m above sea level
Storage temperature
–40 to 70ºC (–40 to 158ºF)
–40 to 85ºC (–40 to 185ºF)
Storage altitude 
level
Below 15,000 m above sea level
Safety compliance
•IEC 60950-1
•EN 60950-1
•CB Certificate/Report
•UL/CSA 60950-1
•CE Low Voltage Directive 2006/95/EC (Europe)
•CCC (China)
•KC (Korea)
EMC compliance
•FCC / ICES-003 Emission (USA/Canada)
•CRISP 22 Emission (International)
•EN55022 Emission (Europe)
•EN55024 Immunity (Europe)
•EN61000-4-2 Electrostatic Discharge
•EN61000-4-3 Radiated RFI Immunity
•EN61000-4-4 Electrical Fast Transients level 4
•EN61000-4-5 Electrical Surge Level  
•EN61000-4-6 RF Conducted
•EN61000-4-8 Power Frequency Magnetic Fields
•EN61000-4-11 Voltage Dips and Interruptions
•EN61000-4-8 Power Frequency Magnetic Fields
•EN61000-4-11 Voltage Dips and Interruptions
•EN61000-3-2 Harmonics (Europe)
•EN61000-3-3 Voltage Flicker (Europe)
MTBF
4,534,733 hrs 
(~517 years) @ 
25ºC
160,000 hrs (~18.3 
years) @ 25ºC
1,708,756 hrs 
(~195 years) @ 
25ºC
1,272,908 hrs 
(~145 years) @ 
25ºC
Support
Thank you for purchasing this NETGEAR product. You can visit  
 to register your product, get help, access the latest 
downloads and user manuals, and join our community. We recommend that you 
use only official NETGEAR support resources.
For the current EU Declaration of Conformity, visit  
.
For regulatory compliance information, visit  
.
See the regulatory compliance document before connecting the power supply.