Netgear FS728TPv2 - ProSAFE 24 Port 10/100 Smart Switch with 4 Gigabit Ports and 24 PoE Ports 사용자 설명서

다운로드
페이지 185
FS728TP Smart Switch FS728TP Smart Switch Software Administration Manual
7-4
Monitoring the Switch
v1.0, December 2007
Emergency – The highest warning level. If the device is down or not functioning 
properly, an emergency log message is saved to the specified logging location.
Alert – The second highest warning level. An alert log is saved, if there is a serious 
device malfunction; for example, all device features are down.
Critical – The third highest warning level. A critical log is saved if a critical device 
malfunction occurs; for example, two device ports are not functioning, while the rest 
of the device ports remain functional.
Error – A device error has occurred; for example, if a single port is offline.
Warning – The lowest level of a device warning. The device is functioning, but an 
operational problem has occurred.
Notice – Provides device information.
Informational – Provides device information.
Debug – Provides debugging messages.
2. Select the minimum severity level for RAM logs.
3. Select the minimum severity level for FLASH logs.
4. Click Apply to update the device.
Memory Log
The Memory Log screen contains all system logs in a chronological order that are saved in RAM 
(Cache).