Netgear FS728TPv2 - ProSAFE 24 Port 10/100 Smart Switch with 4 Gigabit Ports and 24 PoE Ports 관리자 가이드

다운로드
페이지 261
  Chapter 3:  Configuring Switching Information
 
   
|
     
95
FS728TP Smart Switch Software Administration Manual 
2. 
Click Cancel to cancel the configuration on the screen and reset the data on the screen to 
the latest value of the switch
3. 
If you make any configuration changes, click Apply to send the updated configuration to the 
switch. Configuration changes take place immediately.
The following table describes the MSTP status information displayed on the Spanning Tree 
CST Configuration page.
Click Refresh to update the information on the screen with the most current data.
CST Port Configuration
Use the Spanning Tree CST Port Configuration page to configure Common Spanning Tree 
(CST) and Internal Spanning Tree on a specific port on the switch. 
To display the Spanning Tree CST Port Configuration page, click Switching > STP > 
Advanced 
 CST Port Configuration
To configure CST port settings:
1. 
To configure CST settings for a physical port, click PORTS.
2. 
To configure CST settings for a Link Aggregation Group (LAG), click LAGS
Field
Description
MST ID
Table consisting of the MST instances (including the CST) and the 
corresponding VLAN IDs associated with each of them.
VID
Table consisting of the VLAN IDs and the corresponding FID associated with 
each of them
FID
Table consisting of the FIDs and the corresponding VLAN IDs associated 
with each of them.