Make sure that the HDD or SSD is installed on the correct side of the disk tray.
WARNING:
To prevent damage to your system, make sure that the disk tray is correctly
oriented before inserting it into the drive bay.
5.
Insert the disk tray back into the drive bay of the storage system.
For 2-bay and 4-bay systems, insert the disk tray so that the disk tray release latch is near the bottom
of the system.
For 6-bay systems, insert the disk tray so that the disk tray release latch is on the left side of the
system.
6.
Press down on the disk tray handle until it latches closed.
The disk tray is secured in the drive bay.
If the volume that contained the failed disk uses a protected RAID configuration, the system automatically
resynchronizes the volume using the new disk. Resynchronization might take several hours, depending
on the disk size. You can continue to use your storage system, although access is slower until the
volume resynchronization finishes.