KitchenAid 30'' Wall-Mount 600 CFM Canopy Hood, Commercial-Style 설치 가이드

다운로드
페이지 36
8
6. Remove terminal box cover and set aside.
7. Remove knockout from the back of the range hood and install 
a UL listed or CSA approved 
¹⁄₂" (1.3 cm) strain relief. 
8. Place the range hood near its mounting position and run the 
power supply cable through the strain relief into terminal box 
(enough to make connection). 
9. Tighten the strain relief screws.
NOTE: Your range hood requires you to purchase either an 
internal type or an in-line (external type) blower motor system.
For internal blower systems, there are blower motor mounting 
parts in the blower motor installation packet that must be added 
to the range hood prior to mounting the range hood to the wall. 
See the “Install Range Hood Internal Blower Motor” section and 
the instructions supplied with the blower motor.
Install Range Hood
The range hood attaches to the wall by the 2 mounting screws in 
the wood support mounted to the wall in the “Range Hood 
Mounting Screws Installation” section. 
1. Using 2 or more people, hang the range hood on the wall by 
placing the slotted holes in the range hood back over the 
2 screws mounted to the wood support mounted to the wall. 
NOTE: If your installation uses the optional duct cover, the 
vent system needs to be connected to the range hood and 
the duct cover mounted to the top of the range hood before 
tightening the mounting screws. See steps 3 - 5. 
2. Push the range hood up into the narrow slots, align the 
bottom of the hood to the horizontal line, level the hood, and 
tighten the 2 mounting screws.
3. Mark 2 lower mounting hole center point locations. Drill 
¹⁄₈" (0.32 cm) pilot holes if the holes are located into wood. If 
holes are not located into wood, drill two 
³⁄₈" (0.95 cm)  pilot 
holes and insert 10 x 50 mm wall anchors. Install 2 - 6 x 
80 mm screws with D5.3 x 20 mm washers into the lower 
mounting anchors and tighten. 
4. Install 4 - 4.2 x 19 mm screws through the back of the hood 
into the wood support and tighten.
5. Connect vent system to hood. Seal all joints with clamps.
NOTE: If your installation uses the optional full-width duct cover, 
attach the duct cover to the top of the range hood following the 
instructions and using the screws that are provided with the duct 
cover. For information on ordering the optional duct cover, see 
the “Accessories” section. 
Install Range Hood Internal Blower Motor
NOTE: Your range hood requires you to purchase either an 
internal type or an in-line (external type) blower motor system. 
See “Blower Motor System” in the “Accessories” section.
The internal blower system can be mounted for top venting or 
rear venting. For top venting, the mounting bracket and spring 
clip that comes with the blower system will mount to the top 
panel of the range hood. For rear venting, the mounting bracket 
and spring clip that comes with the blower system will mount to 
the rear panel of the range hood. 
Prepare the Internal Blower System
IMPORTANT: Perform steps 1-4 before mounting the range 
hood.
1. Remove grease filters from range hood. See the “Range 
Hood Care” section in the Use and Care Guide.
2. Install the motor support bracket using three 4.2 x 8 mm 
screws. Screw bracket to the inside top or back (alternate 
location on some models), toward the left side of the range 
hood.
3. Install motor spring clip using two 4.2 x 8 mm screws. Screw 
spring clip to the inside top or back (alternate location on 
some models) of the range hood at the proper location for the 
selected motor system. Slide the mounting tab of the spring 
clip through the slot in the panel and secure with the screws. 
Use the inside set of mounting holes for the single motor 
system. Use the outside set of mounting holes for the dual 
motor system.
→ →
A. 4.2 x 8 mm screws (3) for motor support bracket
B. 4.2 x 8 mm screws (2) for motor spring clip
C. Motor support bracket
D. Motor spring clip (single motor assembly location)
E. Motor spring clip (dual motor assembly location)
C
A
D
E
B