Xerox Document Workstation with PlotWorks Support & Software 사용자 가이드
4-30 • PlotWorks User Guide
•
English or metric (ACAD/ACADM only): If the data type is ACAD,
measurements are in English. If the data type is ACADM, Metric is
selected.
measurements are in English. If the data type is ACADM, Metric is
selected.
Ensure the measurement units selected in the Job Editor match the ACAD drawing
units.
units.
•
Remove hidden lines: This option is used during AutoCAD processing
to remove lines behind other planes when 3-dimensional rendering.
to remove lines behind other planes when 3-dimensional rendering.
•
Reverse Z order: This option is only available with DWG Direct
processing. Normally, PlotWorks prints the main AutoCAD image first,
and any XREF files second. As a result, the XREFs are layered on top of
the main image. When the Reverse Z order option is selected, the XREF
files are printed first, making them appear as though they are underneath
the main image.
processing. Normally, PlotWorks prints the main AutoCAD image first,
and any XREF files second. As a result, the XREFs are layered on top of
the main image. When the Reverse Z order option is selected, the XREF
files are printed first, making them appear as though they are underneath
the main image.
AutoCAD actually processes the XREFs as they occur in the DWG file. So your
output using this option can still vary from those generated directly by AutoCAD.
output using this option can still vary from those generated directly by AutoCAD.
•
Scale: If an ACAD scale is selected from the Main tabbed dialog box or
on the grid, that number displays here. You can also set the ACAD scale
here and it will then display on the Main tabbed dialog box and on the
grid.
on the grid, that number displays here. You can also set the ACAD scale
here and it will then display on the Main tabbed dialog box and on the
grid.
•
Plot by: Select this option to print the AutoCAD image by Extents,
Display, Limits, View, or Layout. If View is selected, the View name
field displays:
Display, Limits, View, or Layout. If View is selected, the View name
field displays:
•
View name: (AutoCAD) If Plot by View is selected, you can enter
the name of the view to be printed. If Plot by Layout is selected,
enter the name of the layout to be printed.
the name of the view to be printed. If Plot by Layout is selected,
enter the name of the layout to be printed.
•
View name: (DGN) Prints an area defined in MicroStation under a
specified view name. If you select this Plot By option, you must
enter the correct view name in the View Name field in the Job
Editor. Allowable entries are:
specified view name. If you select this Plot By option, you must
enter the correct view name in the View Name field in the Job
Editor. Allowable entries are:
•the saved view name in Microstation;
•the special view names of 1 through 8 (representing the allowable
MicroStation view window numbers);
MicroStation view window numbers);
•a selection cell name in addition to a view name or number. For
example: topview CELL<linepa> where topview is a name given
to a view and linepa is a named cell.
example: topview CELL<linepa> where topview is a name given
to a view and linepa is a named cell.