4.3 HOLD-UP TIME (@FULL LOAD)
115V / 60Hz : 17 mSec. Minimum.
230V / 50Hz : 17 mSec. Minimum.
4.4 OUTPUT RISE TIME
(10% TO 95% OF FINAL OUTPUT VALUE, @FULL LOAD)
115V-rms or 230V-rms
+ 3.3Vdc : 20ms Maximum
+ 5Vdc : 20ms Maximum
+ 12Vdc : 20ms Maximum
+ 5Vsb : 25ms Maximum
- 12Vdc : 20ms Maximum
The output voltage will remain within specification, in the event that the input power is removed or
interrupted, for the duration of one cycle of the input frequency. The interruption may occur at any
point in the AC voltage cycle. The power good signal shall remain high during this test.
4.2 LOAD CAPACITY SPECIFICATIONS
The cross regulation defined as follows, the voltage regulation limits DC include DC Output
ripple & noise.
LOAD
STM.
+3.3V
+5V
+12V1 DC +12V2 DC
-12V
+5VSB
LHMMHH
0.5A
30A
9.7A
9.7A
0.5A
2A
FULL LOAD
HMMMHH
30A
10.6A
9.7A
9.7A
0.5A
2A
FULL LOAD
LLLLLL
0.5A
0.3 A
1A
1A
0A
0A
ALL MIN
HLLLLL
30A
3A
3A
3A
0A
0A
+3.3V MAX 
other MIN
LHLLLL
0.5A
21A
1.5A
1.5A
0A
0A
+5V MAX
Other MIN
LLLLHL
0.5A
0.3A
1A
1A
0.5A
0A
-12V MAX
other MIN
LLLLLH
0.5A
0.3A
1A
1A
0A
2A
+5VSB MAX
other MIN
LLHHLL
2A
2A
14A
15A
0A
0A
+12V1&+12V2 MAX
Other MIN