Honeywell Bypass Drum Humidifier (HE120A) 설치 설명서

다운로드
페이지 48
HE120 BY-PASS DRUM HUMIDIFIER
69-1860EF—01
6
Fig. 5. Cutting Humidifier opening.
6.
Disassemble the Humidifier; remove the cover by lifting 
up on the front edge and take out the drum components, 
Water Pan, and Motor Plate. 
7.
Position the HE120 Humidifier Housing over the open-
ing (make sure it is level) and mark the five mounting 
holes. See Fig. 6.
8.
Remove the HE120 Humidifier Housing and pre-drill the 
mounting holes using a 1/8 in. drill bit 
9.
Start the three #8 x 3/4 in. Sheet Metal Screws in the 
top holes.
Fig. 6. Marking Mounting Hole locations.
10.
Place the Humidifier Housing over the screws, level the 
housing and tighten the three screws. See Fig. 7.
11.
Secure the bottom of the Humidifier Housing using two 
#8 x 3/4 in. Sheet Metal Screws.
Fig. 7. Mounting Humidifier.
12.
Check that the Humidifier is level.
STARTING HOLE
M13618
MOUNTING HOLES
MOUNTING HOLES
M13619